Avisaro Online Documentation - Wiki
Impressum Kontakt Sitemap

Reset to default

Sometimes it becomes necessary to reset the device or module to default values. Choosing the best ways depends on the product you have and depends on the access which is still possible. Be aware of the following after a reset to default:

• The automatic execution of the script is disabled. Thus, the LEDs will not light up until the script is restarted again. The script itself remains stored.

• The default interface selection is RS232. Reconfigure the desired interface.

 

Choose the best way to perform the reset:

If the SD Slot is available: By issueing commands via the automatically executed 'autorun.txt' file at the SD card, the default values can be activated. This is the easiest and most convenient way.

For all boxes and cubes: By holding the button next to the LED's during the booting period. This is as well a easy and most convenient way.

For Modules: Bridging the I/O Pin number 17 and 18, powering up the module and than release the short-circuit will reset the device to default values

If WLAN is present: Without the need to attach any cables, the module can be set to default values. This way requires some WLAN configuration on your PC and requires to run a Java program. Other than that it is quirte convenient.

If the Data Interface (RS232, I2C, CAN, ...) is available: Commands can be issued to reset the device. Be aware, that no 'Script' is executed, otherwise the Commands are viewed as data and not as commands.