To use the command interface it is substantial that the script is not running:
A script can be easily stopped by using the command RUN MANUAL in a autorun.txt
Use a normal text editor and create a file on the SD card with the name autorun.txt with the following content:
run manual
(press the enter key at the end of the line)
Insert the SD card in the slot of the logger and restart the logger.
All LED's remain off.
Now you can communicate with the logger via interface. Use the refering commands and send it to the logger.
To restart the script just send the commands
run auto
run
Then the command interface is switched off.